top of page

WatchPAT Home Sleep Testing

At Sleep, Snoring & Sinus Clinic Of Florida, we are dedicated to helping our patients enjoy a good night’s sleep. The WatchPAT home sleep apnea testing system is just one example of how we use the latest medical treatments and diagnostic technology to get our patients closer to that goal. This diagnostic test allows us to get meaningful, actionable data about our patients’ sleep without disrupting their routines. Using this system, we may be able to diagnose or rule out sleep apnea for you without you having to complete a traditional in-office sleep study.

How It Works

The WatchPAT home sleep apnea testing system is incredibly easy to use. There are only three places where the system comes into contact with your body: a small sensor taped to your sternum, a watch pad worn on the wrist of your non-dominant hand, and a probe that goes on one of your fingers. You can put the system on in seconds with the help of the illustrated guide included with the system. Once it’s on, you can head to bed and sleep as you normally would.

 

While you sleep, the WatchPAT system will collect a host of data for the doctor to analyze. The system can report how long you sleep, how long you spend in each stage of sleep, and whether you had any sleep apnea events. Once the doctor has this information, they can determine whether you’re suffering from sleep apnea and devise a treatment plan to help you enjoy a more restful night’s sleep.

sleep2-1920w.webp

Why WatchPAT Beats a Traditional Sleep Study

Anyone who has “enjoyed” a broken night’s sleep in a comfortable hotel room or as a guest in someone else’s home can attest that people don’t often sleep well away from their own homes and beds. Unfortunately, a traditional sleep study starts by asking you to do just that, making these sleep studies quite stressful and inconvenient.

 

In contrast, the WatchPAT system allows you to sleep in your own bed, surrounded by your familiar comforts. The system is small and simple, unlike traditional sleep study equipment. If you need to get up during the night (say, to use the restroom), you won’t have to untangle yourself from a host of wires and sensors. You’ll also be able to sleep in whatever positions you prefer. And of course, since you’re spending the night at home, you can practice your normal bedtime and wake-up routines without having to factor in traveling to and from a sleep testing clinic.

The Peripheral Arterial Tone (PAT®)

The Peripheral Arterial Tone (PAT®) signal is a non-invasive measure of the arterial pulsatile volume changes at the fingertip.

It is a proprietary technology used to identify respiratory events. Using specific signal patterns, the algorithm provides two indices used in determining the degree of sleep apnea, Apnea-Hypopnea Index (AHI) and Respiratory Disturbance Index (RDI). The PAT®  Signal is measured from the fingertip by recording finger arterial pulsatile volume changes since the finger has its unique physiology with;

  • High vascular density

  • Convenient site for measurement

  • Tremendous blood flow variability (1-100ccm/100g/sec)

  • Reflection of sympathetic nervous system activation, such that terminates any apnea episode

iStock-814310880-1920w.webp

PAT®️ Technology for Sleep Apnea Identification

The termination of sleep disordered breathing events is associated with an increase in heart rate, blood pressure, and sympathetic activation. This increase in sympathetic activation results in peripheral vasoconstriction. Peripheral Arterial Tonometry (PAT) measures arterial pulse volume changes in the finger as a result of vasomotion (vasoconstriction and vasodilatation). WatchPAT® home sleep apnea tests use the PAT® signal to detect sleep apnea events. The algorithm analyses the PAT® signal together with the pulse rate and the oximetry to accurately diagnose the sleep apnea indices.

normal_breathing-pic-1920w.webp

PAT® technology is clinically validated against Polysomnography

Polysomnography (PSG) is considered the “gold standard” for sleep assessment of Obstructive Sleep Apnea (OSA). Numerous validations studies demonstrate a high degree of correlation in RDI, AHI and ODI during simultaneous recording of WatchPAT and PSG with R= 0.879 (RDI)-0.893 (AHI) and 0.942 (ODI).1

Obstructive-sleep-img-1920w.webp
Sleep-disordered-img-1920w.webp

PAT Technology FAQ

How does WatchPAT detect Apnea, Hypopnea, and Respiratory Effort Related Arousal (RERA) events?

WatchPATM utilizes Peripheral Arterial Tone (PAT), a special physiological signal that mirrors changes in the autonomic nervous system (ANS) caused by respiratory disturbances during sleep. The ANS regulates many of our basic functions and it does this without our conscious control. Among its activities are the regulation of blood vessel size and blood pressure, airflow in the lungs, and the heart’s electrical activity and ability to contract. WatchPAT’s automatic algorithm analyzes the PAT signal amplitude along with the heart rate and oxygen saturation to identify and classify breathing problems while you sleep. Using specific signal patterns, the algorithm provides two indices that allow a diagnosis of sleep apnea:

  • AHI (Apnea/Hypopnea Index) is an index used to calculate sleep apnea severity based on the total number of complete cessations (apneas) and partial obstructions (hypopneas) of breathing per hour of sleep.

  • RDI (Respiratory Disturbance Index) is used to assess the severity of sleep apnea by measuring respiratory efforts, or RERAs (Respiratory Effort Related Arousals). A RERA is an arousal from sleep that follows 10 seconds or more of increased respiratory effort but does not meet the criteria for apnea or hypopnea. The snoring sensor enables the clinician to determine if the respiratory events are obstructive and the body position sensor enables the clinician to determine if there is a positional component to the sleep apnea
     

How does WatchPAT detect rapid eye movement (REM) from the finger?

Rapid eye movement (REM) sleep is associated with considerable attenuation of the PAT signal and physiology coupled with specific variations in the PAT amplitude and rate. Based on this specific variability in the PAT and pulse rate signals, REM sleep stage is differentiated from non-REM sleep. In addition, it is differentiated from the wake state by WatchPAT’s advanced actigraphy algorithms. This is clinically important to prevent under-treatment of apnea if predominantly REM-related.

How does the WatchPAT home sleep apnea test detect sleep architecture?

WatchPAT’s sleep/wake detection is based on data recorded by the built-in actigraph. The propriety software’s automatic actigraph algorithm discriminates between sleep and wake states in normal subjects and those with Obstructive Sleep Apnea (OSA). This algorithm makes WatchPAT’s home sleep apnea test (HSAT) superior to all other actigraph devices—most of them fail when used with OSA subjects. WatchPAT’s sleep/wake algorithm has been validated and published in peer-reviewed journals. The results show very good agreement between actigraphy and PSG in determining sleep efficiency, total sleep time, and sleep latency (agreement 86% in normal subjects, 86%-mild OSA, 84%-moderate OSA, 80% severe OSA).

How does WatchPAT differentiate between respiratory arousals and other events like Periodic Limb Movement (PLM) related arousals and spontaneous arousals?

The algorithms differentiate between respiratory related arousals and Periodic Limb Movement (PLM) related or spontaneous arousals via detection of specific patterns in the PAT signal coupled with the presence or absence of unique dynamics of the pulse oximetry signal.

iStock-466037757-1920w.webp

Prevent up to 20% Misdiagnosis with True Sleep Time

  • WatchPAT calculates AHI and RDI using the patient’s True Sleep Time rather than the recorded time used in most commercially available HSAT’s

  • True Sleep Time reduces the risk of misdiagnosis and misclassification that has been reported up to 20% with using total recording time

true-sleep-image-1920w.webp

Improved Accuracy with Sleep Architecture

WatchPAT’s clinically validated Sleep Architecture provides information on sleep staging including sleep efficiency, sleep latency and REM latency4-5. It also provides the added value of detecting REM related sleep apnea with REM and non-REM AHI.

WatchPAT-pies6-1920w.webp

High Accuracy with Central Sleep Apnea Identification

WatchPAT has been clinically proven to detect all types of apnea events. The Central PLUS Module enables specific identification of Central Sleep Apnea (CSA) and Percent of Sleep Time with Cheyne-Stokes Respiration.

sleep-apnea-image-1920w.webp
iStock-1352833498-1920w.webp

Comprehensive Automated Report in Just Seconds

  • AHI Apnea/Hypopnea per hour

  • Central AHI Apnea/Hypopnea per hour

  • Apnea Episodes through the night

  • Snoring and Body Position

  • Oxygen & Heart Rate (note precipitous drops)

  • Sleep Stages (unique to WatchPAT)

  • Body Position Statistics and Graphic Display

  • Snoring Statistics

  • Sleep Stages Graphic Display

  • Respiratory Indices Chart

  • AHI Severity Scale

growing-page-1920w.webp

WatchPat One Fully Disposable. Fully Reliable

It’s Simple

3 points of contact for outstanding patient compliance with 98% success rate4.

 

It’s Accurate

The WatchPAT Home Sleep Apnea Test is clinically validated with an 89% correlation to PSG5.

 

It’s Reliable

The PAT signal is an approved measure in the 2017 AASM HSAT Clinical Practice Guidelines for Adults with OSA.

Schedule An Appointment

Send us a message!

Thanks for submitting!

bottom of page